Slickline

  • The only UK manufacturer producing all of our Wirelines
    in our own ISO 9001 accredited factory.
  • All Wirelines exceed the requirements of API 9A
  • All Wirelines are 100% weld free
  • All Wirelines are supplied on painted steel reels
  • All lengths are available on request
  • All reels are packed with a unique protective wrap
    for secure transport
  • Wirelines are coated in custom developed inhibitors to
    further prevent corrosion resistance
  • Stock held in the UK and strategic locations worldwide

Wireline

  • The only UK manufacturer producing all of our Wirelines
    in our own ISO 9001 accredited factory.
  • All Wirelines exceed the requirements of API 9A
  • All Wirelines are 100% weld free
  • All Wirelines are supplied on painted steel reels
  • All lengths are available on request
  • All reels are packed with a unique protective wrap
    for secure transport
  • Wirelines are coated in custom developed inhibitors to
    further prevent corrosion resistance
  • Stock held in the UK and strategic locations worldwide

HT (EIPS) Carbon

Nominal Diameter Inches Nominal Diameter mm Minimum Breaking Load lbf Minimum Breaking Load kN Wireline Weight lbs per 1000ft Wireline Weight kgs / 100m Rec. Pulley Diameter Inches Rec. Pulley Diameter mm
0.082 2.08 1460 6.49 18.15 2.72 10 254
0.092 2.34 1830 8.14 22.66 3.39 11 279
0.108 2.74 2490 11.08 31.23 4.67 13 330
0.125 3.18 3300 14.68 41.84 6.26 15 381
0.140 3.56 4200 18.68 52.41 7.84 17 432
0.160 4.06 5500 24.47 68.45 10.24 20 508

UHT Carbon

Nominal Diameter Inches Nominal Diameter mm Minimum Breaking Load lbf Minimum Breaking Load kN Wireline Weight lbs per 1000ft Wireline Weight kgs / 100m Rec. Pulley Diameter Inches Rec. Pulley Diameter mm
0.082 2.08 1610 7.20 18.15 2.72 10 254
0.092 2.34 2050 9.12 22.66 3.39 11 279
0.108 2.74 2730 12.14 31.23 4.67 13 330
0.125 3.18 3665 16.30 41.84 6.26 15 381
0.140 3.56 4600 20.46 52.41 7.84 17 432
0.160 4.06 6005 26.71 68.45 10.24 20 508

316 Stainless

Nominal Diameter Inches Nominal Diameter mm Minimum Breaking Load lbf Minimum Breaking Load kN Wireline Weight lbs per 1000ft Wireline Weight kgs / 100m Rec. Pulley Diameter Inches Rec. Pulley Diameter mm
0.082 2.08 1140 5.07 18.1 2.71 10 254
0.092 2.34 1500 6.67 22.70 3.40 11 279
0.108 2.74 2000 8.90 31.30 4.68 13 330
0.125 3.18 2650 11.79 41.90 6.27 15 381
0.140 3.56 3350 14.90 53.52.50 7.86 17 432
0.160 4.06 4300 19.13 68.60 10.27 20 508
slick2205
Nominal Diameter Inches Nominal Diameter mm Minimum Breaking Load lbf Minimum Breaking Load kN Wireline Weight lbs per 1000ft Wireline Weight kgs / 100m Rec. Pulley Diameter Inches Rec. Pulley Diameter mm
0.082 2.08 1350 6.01 18.00 2.69 10 254
0.092 2.34 1650 7.34 22.60 3.38 11 279
0.108 2.74 2400 10.68 31.10 4.65 13 330
0.125 3.18 3050 13.57 41.70 6.24 15 381
0.140 3.56 3800 16.90 52.30 7.83 17 432
0.160 4.06 4700 20.91 68.30 10.22 20 508
slick6mo
Nominal Diameter Inches Nominal Diameter mm Minimum Breaking Load lbf Minimum Breaking Load kN Wireline Weight lbs per 1000ft Wireline Weight kgs / 100m Rec. Pulley Diameter Inches Rec. Pulley Diameter mm
0.082 2.08 1310 5.83 18.20 2.72 10 254
0.092 2.34 1670 7.43 22.90 3.43 11 279
0.108 2.74 2350 10.45 31.60 4.73 13 330
0.125 3.18 3150 14.01 42.30 6.33 15 381
0.140 3.56 3550 15.79 53.00 7.93 17 432
0.160 4.06 4650 20.68 69.30 10.37 20 508
slick zeron
Nominal Diameter Inches Nominal Diameter mm Minimum Breaking Load lbf Minimum Breaking Load kN Wireline Weight lbs per 1000ft Wireline Weight kgs / 100m Rec. Pulley Diameter Inches Rec. Pulley Diameter mm
0.082 2.08 1650 7.34 18.00 2.69 10 254
0.092 2.34 1920 8.54 22.60 3.38 11 279
0.108 2.74 2500 11.12 31.10 4.65 13 330
0.125 3.18 3300 14.68 41.70 6.24 15 381
0.140 3.56 4050 18.02 52.30 7.83 17 432
0.160 4.06 5150 22.91 68.30 10.22 20 508

MP35N

Nominal Diameter Inches Nominal Diameter mm Minimum Breaking Load lbf Minimum Breaking Load kN Wireline Weight lbs per 1000ft Wireline Weight kgs / 100m Rec. Pulley Diameter Inches Rec. Pulley Diameter mm
0.092 2.34 1680 7.47 24.30 3.64 11 279
0.108 2.74 2244 9.90 33.50 5.01 13 330
0.125 3.18 3200 14.23 44.80 6.70 15 381
0.140 3.56 3500 15.57 56.30 8.43 17 432

Corrosion Protection

Type H2S + CO2 Corrosive Elements (Chloride, Brine, Salt etc) Corrosive Elements (Chloride, H2S + CO2)
Plain Carbon Very poor, may be used in very low H2S (1-2ppm) and CO2 (2-3%)) with inhibitors Good – Wire must be cleaned after use to prevent pitting Extremely poor due to presence of H2S + CO2
UHT Carbon Extremely poor – may not be used in any concentrations even with inhibitors Good – Wire must be cleaned after use to prevent pitting Extremely poor may not be used in any concentrations
316 Stainless Steel May be used in concentrations of up to 30% of CO2 with no H 2S present May be used in concentrations of up to 2-3% May be used in concentrations of CO 2 up to 30% providing chlorides do not exceed 2-3% and no H2S
SLICK 2205 Very good in concentrations of CO2 of up to 35% with no H2S present Excellent. May be used in concentrations of up to 30% Very Good in high chloride + CO2 concentrations with no H2S present
SLICK 6MO Excellent all concentrations Excellent Very Good
SLICK ZERON Excellent Excellent Excellent

Provided that Wirelines are purchased from reputable suppliers they should arrive at the user complete with full certification. This acts as a guarantee to the purchaser that the wireline has been manufactured to a specific quality standard and exhibits the properties recorder on the Test Certification.

Unfortunately with time the combined effect of operating under high tensile, bending fatigue stresses and often in corrosive media at high temperatures causes Wireline ductility to become gradually impaired. Consequently those properties originally certified no longer apply and quality assurance becomes dependant on the experience of the operator and on his/her feel of the wire. The availability of Linetech Portable Wireline Tester can assist in checking the ductility this should be used as part of a full testing programme. Torsion testing is especially useful when operating API Wirelines in conditions where small amounts of H2S may exist since line failure can occur in as little as 12 hours exposure.

Wirelines

Call:

0121 772 9797

or click below for more details and latest prices.

Email Now